The Anesthesia Machine Manufacturer!

 

SantaMed originates from Beilin Technology Co., Limited, a leading manufacturer and supplier in China's in-vitro diagnostic (IVD) industry. Established as a subsidiary dedicated to the international market, SantaMed combines cutting-edge R&D, high-quality production, and global customer focus.

 
  • Trolley Type Anesthesia Machine
    Anesthesia machine has wide range of application in modern surgery, such as Intensive care unit, Operation room and Anesthesiology Department and other departments.
    view more
  • Portable Anethesia Machine
    Santa Medical deliver high precious anesthesia equipment system, the machine is suitable for hospital, clinic and laboratory, it could meet the needs of general anesthesia and medical research on...
    view more
  • Vet Anesthesia Machine
    Santa Medical supply various types of anesthesia machine for veterinary use, it has wide range of application from small pet to large animals or livestock, to ensure they are unconscious, free of...
    view more
 

Why choose us

 

 

Rich experience

Every staff on our team has 10+ years in healthcare -we speak your language and deliver actionable insights, not just generic advice.

 

OEM Tailor Service

100% customized according to your needs,One-to-one support throughout the process from demand analysis to implementation.

 

Products Application

Over the years, SantaMed has expanded into diverse medical fields, offering a comprehensive product portfolio, including:IVD Products & Consumables,Gynecology/Obstetrics Equipment,Operating Room (OR) Solutions, Hospital Furniture etc.

 

 

Composition of anesthesia machine
 

Gas supply and delivery system
The gas supply system includes: compressed gas cylinder or central gas source, one-way valve, relief valve, filter, pressure gauge, gas pressure regulator, flow meter and N2O/O2 proportional interlock control device, shut-off valve, etc.
Anesthesia machines must be equipped with flow meters for various gas sources. The flowmeter units for anesthesia machines are L/min and mL/min (or less than 2L/min flow tubes), both of which read flow tubes to facilitate low-flow anesthesia.
At the same time, it must be equipped with a N2O/O2 proportional interlock control device to ensure that the oxygen concentration level of the output anesthetic gas is not less than 25%. When the oxygen supply is insufficient or interrupted, the nitrous oxide supply is automatically cut off.
Many modern anesthesia machines have a 55L/min oxygen bypass, which can quickly and directly enter the breathing circuit through the emergency interface, which greatly facilitates the oxygen supply operation of clinical anesthesiologists.

 

Anesthetic gas vaporizer
The vaporizer is an important part of the anesthesia machine. Its quality not only marks the manufacturing level of the anesthesia machine, but also affects the effect and success of inhalation anesthesia, and directly affects the safety of the patient.
The basic principle of the vaporizer is to use the changes in the temperature and heat source of the surrounding environment to turn anesthetics into vaporized gas, and a certain amount of carrier gas will carry a part of the gas to carry the saturated anesthetic gas. After it becomes an airflow with a certain concentration of anesthesia vapor, it directly enters the anesthesia circuit.

 

Breathing circuit
The breathing circuit is a combined air circuit device that connects the anesthesia machine to the patient. It delivers anesthesia mixed gas for the patient, and returns the patient's exhaled gas, so as to realize the normal exchange of oxygen and carbon dioxide gas.
It is mainly composed of breathing pipe, CO2 absorption tank, breathing valve, storage bag, mask, computer-controlled manual valve, exhaust valve, pressure limiting valve, open/semi-open valve, etc.

 

Anesthesia ventilator
Anesthesia ventilator has become an essential part of anesthesia machine. Mechanical ventilation has been achieved due to inhalation anesthesia, and it has developed rapidly in recent years. The anesthesia ventilator is fully functional and miniaturized, and its drives are pneumatic and electric.
Most of the anesthesia ventilators matched with the newer portable anesthesia machines are oxygen-driven and electronically controlled. The recent anesthesia ventilator belongs to the built-in electric and electronically controlled ventilator. It can be supplemented by the atmosphere for ventilation without a driver, which can ensure the safety of the patient.

 

Safety monitoring system
Modern general anesthesia machine has safety modular patient monitor systems, which include insufficient oxygen supply alarms, insufficient oxygen supply/interruption nitrous oxide cut-off devices, volume and concentration monitoring parts and fault alarms.
The monitoring part of the anesthesia machine mainly includes inhaled oxygen concentration, exhaled tidal volume, airway pressure, minute ventilation, end-tidal CO2 concentration, and anesthetic gas concentration.
It can process and display various data with a microcomputer, and is equipped with an alarm device system. In particular, the monitoring functions of breathing, circulation, nerve and muscle can be realized, which greatly improves the quality of clinical anesthesia and the safety of patients, and improves the success rate of surgery.

 

Residual gas removal system
The residual gas removal system is used to collect the excess residual gas in the anesthesia machine and the exhaust gas exhaled by the patient, and discharge it out of the operating room through the pipeline to avoid air pollution in the operating room.

 

Anaesthesia Machine Uses & Functions

 
 
01
 

Surgical Procedures

Anaesthesia machines are essential parts of general and specialised surgeries. During general surgery, anaesthesia machines provide pain-free and unconscious care. These machines also support specialised fields such as gynaecology, orthopaedic, neurological, etc.

 
02
 

Emergency Medicine

Anaesthesia machine uses also include providing necessary support to patients in emergencies. The function of the machine is to provide rapid sedation and pain relief to patients with severe trauma, severe pain or emergency surgery.

 
03
 

Pain Management

Another use of Anesthesia machines is to aid patients in pain management. Here, anaesthesia machines provide sedation for procedures that may cause discomfort but do not need complete anaesthesia. Common fields of medicine that use anaesthesia machines for pain management are dental, colonoscopies, and dermatology surgeries

 
04
 

Diagnostic Procedures

Diagnostic procedures such as MRIs, CTs, and other imaging procedures require anaesthesia machines. In these procedures, the patient must stay completely still, and medical professionals use anaesthesia machines to help the patient stay still. Other diagnostic procedures that use anaesthesia machines are endoscopy procedures and their types.

手推车式麻醉机

 

Pre-use Inspection of Anesthesia Machine

 

 

Confirm that the standby emergency ventilator functions properly (in case of serious malfunction of the anesthesia machine).
Confirm that the central oxygen supply system terminal is connected to the anesthesia machine's reinforced hose correctly and has adequate output pressure.
Turn on the anesthesia machine's electrical switch equipment, and confirm that it is in normal status.
Check the flow control system, adjust the gas flow rate to the maximum indicated flow rate, and confirm that the float moves normally before shutting it off.
Check the level of the evaporator's filling water.
Check the low-pressure system of the anesthesia machine.
Check the anesthesia circuit, confirm that the circuit components are correctly connected, that the breathing valve and threaded pipe have no water accumulation or damage, that the CO2 absorber is filled and fresh, and that a humidifier can be installed if necessary.
Check the positive pressure leakage of the anesthesia circuit, close the gas flow, close the anesthesia circuit exhaust valve, select the ventilation switch to the manual mode, block the patient end of the respiratory threaded pipe Y-joint, and quickly oxygenate the circuit to achieve an internal pressure of 30cmH2O, confirming that the pressure remains stable for at least 10 seconds, open the exhaust valve, and confirm that the pressure drops to 0.
Check the anesthesia waste gas removal system for proper connection and unobstructed flow.
Anesthesia machine's mechanical ventilation experiment, connect the simulated lungs on the patient end of the anesthesia circuit, set the ventilation parameters, turn on the mechanical ventilation device, confirm that the tidal volume of the inspiratory period of the simulated lungs matches the ventilation settings, the expiratory period of the bellows can be fully charged, and the breathing valve opens or closes normally.

 

Types of anesthesia machines

Air anesthesia machine

The air anesthesia machine is a semi-open anesthesia device. It mainly consists of a liquid medicine tank, an ether regulating switch, folding bellows, and a suction and exhalation one-way valve and a bellows. The device is lightly applicable and can directly use air and oxygen as a carrier gas to assist in breathing and control breathing to meet various surgical requirements.

DC anesthesia machine

The direct current anesthesia machine consists of high-pressure oxygen, pressure reducer, flow meter, and anesthetic liquid evaporator. The device can only provide oxygen and adjust the concentration of anesthetic gas to be inhaled. There must be other devices in series with the output site for anesthesia.

Closed Anesthesia Machine

The device supplies the patient with a low-flow anesthetic mixture and a one-way activity through the outgassing flap (door). The exhaled gas is re-used through the exhalation flap into the CO2 absorber. Its structure is mainly composed of oxygen supply and nitrous oxide device, gas flow meter, evaporator, CO2 absorber; one-way valve, breathing tube, outgassing valve, storage airbag and so on.

 

 

FAQ

 

 

Q: What are the main components of an anaesthesia machine?

A: Some of the standard components of an anaesthesia machine include ventilators, breathing circuit, gas supply system, vaporizers and monitors and alarms for smooth supply of gas and anaesthesia.

Q: What is the role of the vaporizer in an anaesthesia machine?

A: The role of the vaporizer machine is to provide optimal concentration of anaesthetic gas, adjust and provide the right amount to the patients. Its primary functions include conversion of liquid into vapours, temperature compensation, flow rate and more.

Q: What safety features are built into modern anaesthesia machines?

A: Some of the safety features built into modern anaesthesia machines include alarms systems, gas supply safety, patient monitoring integrations, backup systems, oxygen failure safety device and hypoxia prevention devices.

Q: How often should anaesthesia machine parts be checked and maintained?

A: When considering anaesthesia machine maintenance, be sure to get it inspected by an authorised anaesthetic service provider. You need to service its various components at least annually.

As one of the leading anesthesia machine manufacturers in China, we warmly welcome you to buy cheap anesthesia machine for sale here and get free sample from our factory. Quality products and reasonable price are available.

ambulance stretcher trolley price, lockable medication trolley, medical trolly
Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!